Commercial Appliance Parts Trane Trane are an American manufacturer of residential and commercial air conditioning and heating systems and in 2008 became part of the Ingersoll Rand group. PHC supply many different Trane spare parts and are one of few parts specialists in the UK to hold stock of Genuine Trane. Read this manual thoroughly before operating or servicing this unit. Process: Please open the attachment RT-SVD03L-EN.pdf to view the ReliaTel™ Service Manual. The Table of Contents begins on Page 4 of the Service Manual. If you would like a hard bound copy of this manual please contact your local Trane Parts Center.
Trane Ucp Module Manual User
Installation
Unit Control Module (UCM) 4.2 Retrofit
Model VAV
Models
“A” and later Design Sequence
VAV
NOTICE:
Warnings and Cautions appear at appropriate sections throughout this manual. Read these carefully.
WARNING – Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION – Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. It may also be used to alert against unsafe practices.
CAUTION – Indicates a situation that may result in equipment or property-damage-only accidents.
General
The purpose of this installation manual is to provide application, functional and calibration information for the Trane Retrofit package. Examples and charts are provided to enhance the understanding of this information.
Introduction
The DDC/VAV retrofit kit consists of the UCM control assembly, a Honeywell™ or Belimo™ actuator (both optional), and various accessories such as zone sensors, transformers, flow sensors, etc. This manual is intended to show how to apply, install and configure the DDC/VAV Retrofit kit. It is intended to provide information specific to the VAV retrofit. Refer to VAV-SVX01C-EN for complete DDC/VAV system wiring, installation and programming instructions.
Applications
The retrofit kit may be applied to pneumatic terminals by replacing the pneumatic actuator with an electric actuator or electrically controlled terminals by either using the existing electric actuator or by replacing it with one provided by Trane.
The kit may be used on existing shutoff, shutoff hot water reheat, shutoff with up to three stages of electric heat, and fan powered (both parallel and series) cooling only, hot water, and electric reheat units.

Note: Fan powered units have only two stages of reheat available.
Dual duct units may also be retrofitted using two sets of controllers. The kit has also been applied to constant volume reheat systems where the retrofit kit is used to control duct coils.
The kit has been tested on VAV terminals of several major manufacturers. It is mandatory for unit to have an external shaft to function properly with the direct coupled actuators offered.
© 2005 American Standard All rights reserved | VAV-IN-24 |
Contents
Installation/Startup/Commissioning | 2 | |
Notice/Introduction | 2 | |
Application | 2 | |
Hardware | 4 | |
Installation | 5 | |
Commissioning | 6 | |
Installation
Unit Control Module (UCM) 4.2 Retrofit
Model VAV
Models
“A” and later Design Sequence
VAV

NOTICE:
Warnings and Cautions appear at appropriate sections throughout this manual. Read these carefully.
WARNING – Indicates a potentially hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION – Indicates a potentially hazardous situation which, if not avoided, may result in minor or moderate injury. It may also be used to alert against unsafe practices.
CAUTION – Indicates a situation that may result in equipment or property-damage-only accidents.
Trane Ucp Module Manual Transmission
General
The purpose of this installation manual is to provide application, functional and calibration information for the Trane Retrofit package. Examples and charts are provided to enhance the understanding of this information.
Introduction

Trane Ucp Module Manual Download
The DDC/VAV retrofit kit consists of the UCM control assembly, a Honeywell™ or Belimo™ actuator (both optional), and various accessories such as zone sensors, transformers, flow sensors, etc. This manual is intended to show how to apply, install and configure the DDC/VAV Retrofit kit. It is intended to provide information specific to the VAV retrofit. Refer to VAV-SVX01C-EN for complete DDC/VAV system wiring, installation and programming instructions.
Applications
The retrofit kit may be applied to pneumatic terminals by replacing the pneumatic actuator with an electric actuator or electrically controlled terminals by either using the existing electric actuator or by replacing it with one provided by Trane.
The kit may be used on existing shutoff, shutoff hot water reheat, shutoff with up to three stages of electric heat, and fan powered (both parallel and series) cooling only, hot water, and electric reheat units.
Note: Fan powered units have only two stages of reheat available.
Trane Ucp Module Manual Wiring
Dual duct units may also be retrofitted using two sets of controllers. The kit has also been applied to constant volume reheat systems where the retrofit kit is used to control duct coils.
Trane Ucp Module Manual Diagram
The kit has been tested on VAV terminals of several major manufacturers. It is mandatory for unit to have an external shaft to function properly with the direct coupled actuators offered.
Trane Ucp Module Manual Pdf

© 2005 American Standard All rights reserved | VAV-IN-24 |
Contents
Installation/Startup/Commissioning | 2 | |
Notice/Introduction | 2 | |
Application | 2 | |
Hardware | 4 | |
Installation | 5 | |
Commissioning | 6 | |
